The manufacturers of stainless steel surgical instruments are consistent in their recommendations for the use of Neutral pH detergents and the "proper sequence of cleaning treatments" to optimize surgical instrument care and the sterilization of reusable surgical instruments. The foundation of their recommendations are based on a sequence of chemical and mechanical treatments which include using: Neutral pH chemicals, combination cleaning agents (enzymatic enzyme detergents), cold water pre-wash, elevated temperature detergent cleaning, redundant purified water rinses, and elevated temperature (above boiling point) hot air drying.
Hydraulic Height Adjustment options Surgical Instrument Prep and Pack Tables Surgical Scrub Sinks






non-irritating Surgical Instrument Cleaner
100% Biodegradable Surgical Instrument Cleaner
Neutral pH Surgical Instrument Cleaner
Free Rinsing Surgical Instrument Cleaner
Surgical Instrument Washer Decontamination Racks with Luer lock fittings and silicone adapter connetions for cleaning Cannulated surgical instruments inside and out. Cannulated surgical instruments are held securely in place for effective cleaning inside and out eliminating the costs and risks associated with manually cleaning Cannulated surgical instruments.
Surgical Instrument Decontamination "efficacy of disinfection was 100%"
Surgical Instruments cleaned in a Surgical Instrument Washer with automated Ultrasonic Surgical Instrument Cleaning (Washer Decontaminator, Washer Disinfector) using an Enzymatic enzyme detergent Surgical Instrument cleaner: "evaluation of Surgical Instrument Washer with automated Ultrasonic Surgical Instrument Cleaning confirmed that the efficacy of disinfection was 100%". "All surgical instruments and utensils tested were sterile at the completion of the process."
Surgical Instrument Washers with Ultrasonic Surgical Instrument Cleaner (Surgical Instrument Washer, Decontaminator, Washer Disinfector) will provide critical cleaning: "Proper Sequence of Washer Treatments" the Prerequisite for Disinfecting Surgical Instruments and/or "Sterilizing Surgical Instruments." The "Proper Sequence of Surgical Instrument Washer Treatments" includes a series of mechanical and chemical treatments.
Surgical Instrument Washers
compact surgical instrument washer Dimensions:
External Size Countertop Model:
31.5” W x 27.5” D x 34.6” H
External Size Under Counter Model:
31.5” W x 27.5” D x 33.5” H
Internal Chamber Size:

20.0” W x 21.0” D x 21.3” H
Surgical Instrument Washer Cycle Temperatures:
Cold Water Pre Wash Cycle:
ambient to 95º F
Wash Enzymatic/Detergent Cycle: 131º F to 137º F
Elevated Thermal Rinse Cycle[s]:
194º F to 209º F
Hot Air Dry Cycle:


158º F to 230º F
Surgical Instrument Washer Cycle Times: (plus Dry Time)
Normal Wash:
12 to 15 minutes (range due to Temperature specified)
Intensive Wash: 22 minutes (reserved for heavy dried-on encrustation)
Surgical Instrument Decontamination Washer
Weight of DS500 DRS:
Weight empty: 150 kg, 330 lb [does not included weight of chemical, water, or solutions]
Countertop Surgical Instrument Washers cut costs
Undercounter Surgical Instrument Washers create space.



STATIM 5000 Tabletop Sterilizer
STATIM 2000 Tabletop Sterilizer
Customer Service: Joan Hinchman
1-800-341-7048, Fax: 1-800-704-2815
Send can a TEXT message to Customer Service by entering text in the space below. 'Click' on the Submit button to send your message. Include your Contact Information within your message to enable our reply.
For more information go to:
Technical Support: John Temple
1-509-747-5027
Send can a Text message to Technical Support by entering text in the space below. 'Click' on the Submit button to send your message. Include your Contact Information within your message to enable our reply.
For more information go to: